X600 SPECIFICATIONS
All figures obtained after 1 hour warmup, with regulated 120 VAC power line. See manual
notes about AC power line regulation.
Gain 30 dB
Freq. Response -0 dB at DC, -3 dB at 100 kHz
Power Output 600 watts maximum @ 1% THD, 1 kHz, 8 ohms
Distortion refer to accompanying distortion curve
Maximum Output Voltage plus, minus 105 volts
Maximum Output Current plus, minus 25 amps
Input Impedance 22 kohm balanced
Damping factor 60 ref 8 ohms nominal
Slew rate plus, minus 50 V/uS
Output Noise 500 uV unweighted 20-20 kHz
Random noise floor approximately 2 uV
Dynamic range 153 dB (random noise floor to peak output)
Balanced CMRR -85 dB @ 1 kHz (input common mode rejection ratio)
DC offset < 100 mv
Power Consumption 600 watts idle, 1800 watts maximum
Temperature 20 degrees C. above ambient typical
Dimensions 19 " W x 22" D x 10.5" H
Shipping Weight 150 lbs.